8528-M372-O1 Rev E PZ3000 Series
10
OPERATION
1. Press and hold (approximately 2 seconds) the ON/OFF key until the scale is powered up.
2. With no weight on the scale, press the ZERO key.
1
3. After a brief moment, the display will show
4. The scale is now “zeroed” and ready for use.
5. Place container on the scale, the weight of the container will be displayed.
6. Press the ZERO key to return the scale to zero.
7. Add your first ingredient to the desired weight; re-zero the scale for the second ingredient by
pressing the ZERO key.
8. Add the second ingredient to the desired weight and re-zero the scale for the next ingredient
by pressing the ZERO key.
9. Continue adding ingredients in the same manner of operation.
10. After completion, remove the container and ingredients from the scale.
11. Press the ZERO key to re-zero the scale.
12. You are now ready to begin again.
1
Instead of pressing the ZERO key, you can zero the scale by passing your hand over the
“Lite Way” photo eye (if enabled) or with the optional Foot Switch (PZFS) or the mountable
Pushbutton (PZPB).
Locking the Weighing Units
If desired, the weighing units can be locked to a specific unit. For example, if during Setup and
Calibration, the scale was configured and calibrated in Pounds Only and you only want to weigh
in Pounds/Ounces with the Fraction displayed, you would need to perform the following:
1. Press and hold (approximately 2 seconds) the ON/OFF key until the scale is powered up.
2. Press the UNITS key until the desired weighing units is shown on the display (the
annunciators and/or fraction for the desired unit are turned on).
3. Press and hold the ON/OFF key for approximately 2 seconds. The scale will beep and
the display will show LoC, indicating the selected weighing unit is now locked.
4. Once the weighing units are locked, the scale will always power up in the locked units and
not in the units the scale was calibrated in. Note that even though the weighing units are
locked, pressing the UNITS keys will still step through the alternate units.
5. To unlock the weighing units, press and hold the ON/OFF key for approximately 2
seconds. The scale will beep and the display will show UnLoC.
CARE AND MAINTENANCE
The heart of the PZ3000 Ingredient scale is a precision load cell located in the center of the scale
base. It will provide accurate operation indefinitely if protected against overload of scale capacity,
dropping items on scale, or other extreme shock.
DO NOT submerge, pour or spray water directly on the scale base or weight display.
DO NOT expose the scale base or display to direct sunlight or temperature extremes.
DO NOT place the scale base or display in front of heating/cooling vents.
DO NOT use acetone, thinner or other volatile solvents for cleaning.
DO clean the scale base or display with a damp soft cloth and mild non-abrasive detergent.
DO remove power before cleaning with a damp cloth.
DO provide clean AC power and adequate protection against lightning damage.
DO keep the surroundings clear to provide clean and adequate air circulation.